Product Description
* Load isolating switches are widely applied to distribution system and automation system in building, power, petrochemical and other industries.
* The acceleration mechanism with instantaneous release of spring storage achieves fast connection or separation, which has nothing to do with the speed of operation handle, and greatly improves the ability of extinguishing arc.
* The shell made of glass fiber reinforced unsaturated polyester resin has good flame retardancy, dielectric properties, carbonization resistance and impact resistance.
* The parallel double breakpoint contact has self cleaning effect.
* All contact materials are copper plated silver alloy with two separate contact surfaces.
* The distance is large.
* In the "O" position, you can use three locks to lock the handle at the same time, and reliably avoid misoperation.
* The switch is beautiful, novel and concise, with small volume and complete function.
Technical data
Model |
|
|
WOT160F |
WOT200F |
WOT250F |
Rated insulation voltage and raged operational voltage AC20/DC20. Dielectric strength. Rated impulse withstand voltage. |
Pollution degree 3 50Hz 1min. |
V KV KV |
750 10 12 |
1000 10 12 |
1000 10 12 |
Rated thermal current and rated operational current AC20/DC20 ...with minimum conductor cross section |
Free air. Closed environmen. Cu. |
A A mm² |
160 125 70 |
200 200 95 |
250 250 120 |
Rated operational current, AC-21A |
≤500V 690V 1000V |
A A A |
160 160 160 |
200 200 200 |
250 250 250 |
Rated operational current, AC-22A |
≤500V 690V 1000V |
A A A |
160 160 160 |
200 200 200 |
250 250 250 |
Rated operational current, AC-23A |
≤500V 690V 1000V |
A A A |
160 80 80 |
200 200 135 |
250 250 135 |
Rated operational current/ poles in series, DC-21A...23A |
24...110V 220V 440V 660V |
A A A A
|
160/1 160/1 160/2 160/3 |
200/2 200/2 200/3 200/4 |
250/2 250/2 250/3 250/4 |
Rated operational current/ poles in series, DC-21B |
800V 1000V |
A A
|
160/5 160/6 |
200/5 200/6 |
250/5 250/6 |
Rated operational power, AC-23A |
230V 400V 415V 500V 690V |
KW KW KW KW KW |
45 75 75 75 75 |
60 110 110 132 200 |
75 140 145 170 250 |
Rated breaking capacity, AC-23A |
≤500V 690V |
A A |
1000 640 |
1600 1600 |
2000 2000 |
Rated conditional short-circuit current Ip (R.M.S) and corresponding max.allowed cut-off current îc. The cut-off current îc refers to values listed by fuse manufacturers (single phase test acc.to IEC60269) |
100KA, 500V gG/aM |
KA A |
30 100/250 |
40.5 315/315 |
40.5 315/315 |
80KA, 690V gG/aM |
KA A |
24 200/250 |
40.5 355/315 |
40.5 355/315 |
|
Rated short-time withstand current(R.M.S)lcw |
≤1000V, 0.15s ≤1000V, 0.25s ≤1000V, 1s |
KA KA KA |
7 7 4 |
15 15 8 |
15 15 8 |
Rated short circuit making capacity |
≤1000V |
KA |
12 |
30 |
30 |
Rated capacitor power (the capacitor ratings are limited by the fuse link.) |
415V 500V 690V |
kVAr kVAr kVAr |
65 85 125 |
100 120 160 |
115 135 190 |
Power loss/pole |
At rated operational current |
W |
6.5 |
4 |
6.5 |
Mechanical endurance |
|
Oper |
20000 |
20000 |
20000 |
Weight without accessories |
3P switch |
kg |
1.1 |
1.2 |
1.2 |
Terminal screw specifications Terminal tightening torque Operating torque |
Metric thread (diameter*length). Locking torque requirements. 3-pole isolation switch. |
mm Nm Nm |
M8/25 15-22 7 |
M8/25 15-22 7 |
M8/25 15-22 7 |
Dimension
Attachment overview
I have a client in Iran. He want US-52 and SS-22 speed controller in October. I sent a PI to him after sending price and freight charge, but i forgot to add freight...
This month our company launched a voucher, in order to appreciate the support from clients. When the client's goods value reached the setted amount, the voucher will...
Winston Wish You Marry Christmas!
Time in a hurry, in the beginning of the new year, we will be better customer service, quality is our culture, to give customers what they want. Winston returen work...